IEC60092 Offshore & Marine Cables
MariTox Marine Flame Retardant Medium Voltage Cables MariTox Marine Flame Retardant Power & Control Cables MariFlex Marine Fire Resistant Power & Control Cables other

Power Distribution Cables

600/1000V single conductors Type E,X,S, LSE, LSX,T distribution cables

Construction

Conductor: Stranded copper conductor tin or alloy coated where necessary for application.

Separator tape: optional

Insulation: Type X, E, T, T/N, S, P, LSX, LSS or LSE according to IEEE 1580 2010.

Shielding: optional

Jacket: Type T, CP, N, CPE, L, P or TPO jacket (optional for Type P with HD thicknesses)

Armor: optional and shall be nonmagnetic

Sheath:

Type T, CP, N, CPE, L, P or TPO sheath (optional except for tinned copper braid armour and CWCMC)

Optional: For halogen-free constructions, Type LSX, LSE or LSS insulation shall be used with a Type L or TPO

jacket/sheath.

Table B.1—Typical dimensions and weights; single-, two-, three-, and four-conductor 600/1000 V; Type E, X, S,

LSE, LSX, and T distribution cables

Number of conductors AWG /kcmil Unarmored Armored Armored and sheathed
Nom. dia. (in) Approx. weight (lb/1000 ft) Nom. dia. (in) Approx. weight (lb/1000 ft) Nom. dia. (in) Approx. weight (lb/1000 ft)

1

14 0.22 32 0.28 45 0.38 77

1

12 0.24 42 0.3 55 0.4 89

1

10 0.27 58 0.33 74 0.43 111

1

8 0.33 87 0.39 105 0.49 147

1

6 0.36 121 0.42 142 0.52 187

1

4 0.41 177 0.47 201 0.6 268

1

2 0.47 261 0.53 288 0.66 363

1

1 0.57 348 0.63 379 0.75 459

1

1/0 0.61 423 0.67 456 0.79 540

1

2/0 0.66 519 0.72 554 0.88 678

1

3/0 0.71 635 0.77 672 0.93 803

1

4/0 0.77 781 0.83 821 0.99 962

1

250 0.88 954 0.94 999 1.11 1167

1

300 0.93 1122 0.99 1169 1.16 1345

1

350 0.98 1289 1.04 1339 1.21 1524

1

400 1.03 1453 1.09 1506 1.26 1698

1

500 1.11 1783 1.17 1839 1.34 2045

1

600 1.22 2136 1.28 2201 1.45 2425

1

750 1.33 2628 1.39 2699 1.56 2941

1

1000 1.48 3440 1.54 3518 1.77 3884

NOTE—Cables with Type T, S, LSE, and LSX insulated conductors will vary from those sho wn.
These values are for reference purposes only and should not be construed as requirements. imensions are based on the use of Class B conductors. Weights of armored constructions are based on aluminum braid armor. It is recommended that the user/specifier contact the manuf acturer for manufacturer specific values.